Specifications

· High flux, up to 32 samples can be extracted each time

· Rapid temperature rise, improving the efficiency of lysis and elution

· Short extraction time, 30-60min to complete the extraction

· With UV disinfection function, effectively eliminate pollution
 
Availability:

Product features
· Fully automatic and high efficiency:Automatic nucleic acid extraction 0.5-1 hour/time, up to 32 samples can be extracted each time, high nucleic acid yield.
· 8 heating strips with independent temperature control, from room temperature to 100 degrees Celsius in less than 90s, firmware upgradeable, customizable whole plate heating.
· Powerful program editing function, flexible and efficient to define your application, can meet different reagent requirements.
· Open reagents, can use all brands of magnetic beads nucleic acid extraction kits.
· Friendly human-computer interaction:High-definition 10-inch LCD touch screen, built-in user and engineer dual interface, convenient for users to customize parameters.
· More stable structure:The design of screw rod and timing belt ensures operation accuracy and speed, and double guide rails ensure efficient extraction.
· More functions:Equipped with ultraviolet lamp disinfection function to ensure no pollution in the operating space, constant temperature control equipment, two modes of whole board and multiple channels can be switched, firmware can be upgraded, and full-plate heating can be customized.


Technical specifications

Product nameBIO-DL 32 Nucleic Acid Extractor
Item number59F21011
Processing volume20μL ~ 1000μL
Maximum sample throughput2*96 deep well plate with 1-32 samples
Magnetic bead recovery rate≥95%
Heating temperatureRoom temperature - 100℃, Single-well system temperature precision: ±1℃, temperature difference between each wells: ±1℃
Operating environment temperature5℃~40℃
Operating humidity≤80%
Shake and mixFast, medium and slow speed can be adjusted to meet different needs, stepless speed adjustment, level can be set ex-warehouse.
Applicable reagent typesMagnetic Method
Operation interface10-inch LCD touch screen
Difference between extraction wellsCV≤3%
Sterilization methodUV
Set interfaceSwitchable interface for user and engineer
Instrument interfaceUSB
physical dimension430mm*420mm*385mm
Gross weight26kg
Input voltage100-240V、50/60HZ



Previous: 
Next: 

Related Products

 
Specifications

· Raw material: Virgin medical grade PP, more stable, temperature compatible from -80°C to 121°C

· Produced in 100000 level GMP clean room. Fully automated production

· Raised rim design, suitable for adhesive and heat sealing

· RNase, DNase, Human Genomic DNA Free. Nonpyrogenic
 
0
0
 
Specifications

· Clean and pollution-free

· High quality airtightness

· Advanced technology, no bending deformation

· Strong adaptability, adaptable to many brands of pipettes
0
0
 
Specifications

· Large LCD display provides visual confirmation of remaining battery charge and speed settings

· Light weight and ergonomic design

· Pipetting speed can be controlled simply and adjusted steplessly

· Adjustable motor speed (3 parts motor speed for choice)

· Pipette fillers for use with pipettes from 0.1-100ml

· Efficient lithium polymer recharge battery ensures numbers of dispensing is approx, 2000(with a 25ml pipette) without recharge

· 50ml can be absorbed within 10s
0
0
 
Specifications

· Handy button operation

· Lightweight, ergonomic design

· Easy to use, easy self-calibration

· Simple and bright, in line with the colour aesthetic design

· Fast set and lock pipetting range

· Autoclavable nozzle fittings

· High accuracy ensures exact results

· Different colors mark different ranges
0
0
 
Specifications

· High flux, up to 32 samples can be extracted each time

· Rapid temperature rise, improving the efficiency of lysis and elution

· Short extraction time, 30-60min to complete the extraction

· With UV disinfection function, effectively eliminate pollution
 
0
0
 
Specifications

· Suitable for BIO-DL Genex and Colour series pipettes

· Non-slip material shelf ensures stable suspension of pipettes

· Convenient and flexible

· Compatible with various other brands of pipettes.
 
0
0
 
Specifications

· High efficiency and easy to use

· Suitable for nucleic acid extraction 96 deep-well plate

· Meet a large volume number of pipetting needs

· Strong chemical corrosion resistant and aging material

· Built-in elastic sealing structure
0
0
Specifications

· Range of working wavelength is from 400nm to 750nm

· 8-channel vertical optical system

· Three kinds of linear vibration plate function

· Industrial-grade color LCD display

· Super fast reading speed of 8 seconds
0
0
We are comprehensive company integrating R&D, production and trade, and has a worldwide sales network and service centers.

QUICK LINKS

CONTACT US

  +86-15800027567
  4008-216-837
  overseas@bio-dl.com
  12#402, No.201 Minyi road, Songjiang Dist., Shanghai, China

NEWSLETTER

subscribe to our newsletter to get allour news in your inbox
© 2022 Shanghai BIO-DL Science Instrument Co., Ltd . All rights reserved.